Eaton S811+V50N3S

EATON S811+V50N3S V Frame Non-Combination Soft Starter With Digital Interface Module, 21.6/26.4 VAC V Coil, 3 Poles, NEMA 0/1/3R/4/4X/7/9/12 Enclosure
NEMA Contactors and Starters
7289234 S811+V50N3S
Eaton
$0.00 / ea

  • Amperage Rating: 500
  • Coil Voltage: 21.6/26.4
  • Connection Type: Lug
  • Dimensions: 11.05 in W x 7.39 in D x 16.57 in H
  • Enclosure Type: NEMA 0/1/3R/4/4X/7/9/12
  • Frequency Rating: 47/63
  • Motor Power: 450 hp, 500 hp
  • Number of Poles: 3
  • Operating Temperature: -30 to 50
  • Overload Relay: Solid State
  • Phase: 3
  • Series: S811
  • Timing: 0.5 to 18
  • Type: V Frame Non-Combination
  • Voltage Rating: 200 to 600
  • Wattage: 300
Eaton S811+ soft starter, 500 A, V-frame, Three-pole, 200-600 V operating voltage, 47-63 Hz, 1-2 conductors, #2/0 AWG to 500 kcmil wire, 120 Vdc, 240 Vac, Modbus RTU, NEMA 0, LCD display, -30пїЅC to -50пїЅC, 24 V power
  • Features
  • Communication capabilities with various protocols
  • Digital interface module (DIM) provides an intuitive, easy to use human interface with powerful configuration capabilities to maximize system performance
  • Door or device mounted dim enables users to safely configure, commission, monitor and troubleshoot the system at the electrical panel without opening the enclosure door
  • System operating parameters can be monitored enterprise wide through a communications network
  • Increase uptime by providing data for process management and preventive diagnostics
  • Run bypass mode greatly reduces internal heating created by the greater power dissipation in the SCRs
  • Bypass contactors directly connect the motor to the line and improves system efficiency by reducing internal power losses
  • Internal solid state overload protection provides accurate current measurement and trip settings
  • Internal run bypass contactors and overload protection eliminate the need for additional devices, reducing enclosure sizes minimizing installation and wiring time and reducing overall assembly size and cost
  • Wide range of overload FLA settings and a selectable trip class offers users the flexibility to fine tune the starter to match specific application requirements
  • Variable ramp times and torque control settings provide unlimited starting configurations, allowing for maximum application flexibility
  • Kick start feature enables soft starting of high friction loads
  • Soft stop control for applications where an abrupt stop of the load is not acceptable
  • Pump control option with sophisticated pump algorithms on both starting and stopping that minimize the pressure surges that cause water hammer
  • 6 SCRs control all 3 motor phases, providing smooth acceleration and deceleration performance
  • Soft acceleration and deceleration reduces wear on belts, gears, chains, clutches, shafts and bearings
  • Reduce the peak inrush current's stress on the power system
  • Minimize peak starting torque to diminish mechanical system wear and damage