Littelfuse JLLN050.TXP
Littelfuse POWR-GARD JLLN050P Fast Acting Fuse, 50 A, 300 VAC/160 VDC, 20/200 kA, Class T, Cartridge Body
                                 Class T Fuses 
                                
                            
                                    7418927
                                        JLLN050.TXP
                                
                                
                                        
                                        Littelfuse
                                
                            
                                
                                
                                                                        
                                            
                                            $0.00
                                        
                                        
                                            / ea
                                        
                                                                    
                        
- Amperage Rating: 50
 - Body Size: 0.562 in Dia x 0.875 in L
 - Body Type: Cartridge
 - Class: T
 - Indicating/Non-Indicating: Non-Indicating
 - Interrupt Rating: 20/200
 - Material: Melamine
 - Mounting Type: Holder
 - Series: JLLN
 - terminal type: Clip
 - Voltage Rating: 300 VAC/160 VDC
 
Littelfuse POWR-GARD Fast Acting Fuse, Series: JLLN, Non-Indicating, 50 A, 300 VAC/160 VDC, 20/200 kA Interrupt, Class: T, Clip Terminal, Holder Mounting, Cartridge Body, Melamine, 0.562 in Dia x 0.875 in L Body
                        - Features
 
- Protection of individual electric service and meters
 - Main switches containing class T fuses may be used to provide compact protection for meter stacks
 - Molded case circuit breaker load centers and panel boards have increased interrupting ratings when series rated with Littelfuse® class T fuses
 - Typical 3-pole class T fuse blocks require less than 50% of the panel area required for class R fuse blocks
 - Switch enclosures, fuse pullouts and other equipment using class T fuses are often correspondingly more compact
 - Extremely current limiting stops damaging short circuit current faster than any mechanical protective device
 - Fast acting overload protection to equipment such as variable speed drives, rectifiers and other equipment containing surge-sensitive components
 - Current limiting design greatly reduces damage to equipment caused by heating and magnetic effects of short circuit currents
 - Extremely current limiting design often permits use of readily available, less costly equipment
 - Compact design
 - Copper caps
 - Silver plated