Fluke Corporation FLUKE-289/FVF
Fluke FLUKE-289/FVF Digital Multimeter Kit, 1000 VAC, 10 A, 500 Ohm to 50 MOhm, VGA Dot Matrix Display
Meters
6961949
FLUKE-289/FVF
Fluke Corporation
$0.00
/ ea
- Accuracy: 0.025% VDC, 0.4% (True RMS) VAC
- Amperage Rating: 10
- Battery Type: (6) AA Alkaline, NEDA 15 A/IEC LR6 V
- Capacitance: 1 nF to 100 uF
- Dimensions: 12.2 x 10.63 x 3.94
- Diode Test: Yes
- Display Type: VGA Dot Matrix
- Frequency Rating: 999.99
- Material: Hard Plastic
- Peak Hold: Yes
- Resistance: 500 Ohm to 50 MOhm
- Safety Rating: CAT IV 600 VAC/VDC, CAT III 1000 VAC/VDC
- Temperature Rating: -328 to 2462
- Voltage Rating: 1000
Fluke Digital Multimeter Kit, 1000 VAC, 10 A, 999.99 kHz Frequency, 500 Ohm to 50 MOhm Resistance, Safety Rating: CAT IV 600 VAC/VDC, CAT III 1000 VAC/VDC, 1 nF to 100 uF Capacitance, 0.025% VDC, 0.4% (True RMS) VAC Accuracy, VGA Dot Matrix Display, (6) AA Alkaline, NEDA 15 A/IEC LR6 V Battery, Peak Hold: Yes, Yes Diode Test, 12.2 x 10.63 x 3.94 in Dimensions, -328 to 2462 deg F, Hard Plastic
- Features
- TrendCapture quickly graphically displays logged data session to quickly determine whether anomalies may have occurred
- Zoom on trend provides unprecedented ability to view and analyze TrendCapture data, zoom in up to 14 times
- Selectable AC filter (smoothing mode) helps display a steadier reading when the input signal is changing rapidly or noisy
- Adjustable recording and auto-hold thresholds, specify a percentage change in the readings that begins a new event
- Large 50000 count, 1/4 VGA display with white backlight, multiple sets of measurement information can be simultaneously displayed at the same time, hard plastic enclosure
- Logging function with expanded memory for unattended monitoring of signals over time, using on board TrendCapture users can graphically review logged readings without needing a PC
- Stores up to 15000 recorded events, on board help screens for measurement function
- Saved measurements allow to name and recall measurements made in the field, real time clock for automatic time stamping of saved readings
- Cat IV 600 V, Cat III 1000 V safety rating, 50000 count, 1/4 VGA display with white backlight, -200 to 1350 deg C temperature
- True-RMS AC voltage and current for accurate measurements on complex signals or non-linear loads, AC bandwidth specified to 100 kHz, 6 AA alkaline batteries, NEDA 15A IECLR6, voltage DC, 0.025%, voltage AC, 0.4% (True-RMS)
- Relative mode to remove test lead resistance from low Ohm or capacitance measurements, voltage DC, 0.025%, voltage AC, 0.4% (True-RMS) accuracy
- Resistance range - 500 Ohm, 5 kOhm, 50 kOhm, 500 kOhm, 5 MOhm, 50 MOhm, 500 MOhm with accuracy of +/- 0.05%
- Capacitance range 1 nF, 10 nF, 100 nF, 1 uF, 10 uF, 100uF, 1000 uF, 10 mF, 100 mF with accuracy of 1%
- Frequency range 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz with accuracy of +/-0.005%
- 100 hour min, 200 hour in logging mode
- Optional infrared connector via Fluke® IR3000 FC