Eaton TRSGF15W

Eaton TRSGF15W GFCI TR Self Test Duplex 15A 125V WH
Receptacles
7463502 TRSGF15W
Eaton
$0.00 / ea

  • Amperage Rating: 15
  • Color: White
  • Dimensions: 4.2 in L x 1.68 in W x 1.27 in D
  • Enclosure: IP65
  • Frequency Rating: 60
  • Material: Thermoplastic
  • Nema Rating: NEMA 5-15R
  • Number of Poles: 2
  • Number Of Wires: 3
  • Series: TRSGF
  • Temperature Rating: -35 to 66
  • terminal type: Back/Side Wire
  • Type: Duplex Tamper-Resistant
  • Voltage Rating: 125
Eaton ground fault circuit interrupter receptacle, 15A, 125V, Back wire and side wire, GFCI, White, Brass, Receptacle, Tamper resistant, PVC, 5-15R, Two-pole, three-wire, grounding
QTY
  • Features
  • If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow notifying the user there is no power and the device must be replaced
  • Performs periodic self-tests to ensure integrity of GFCI protection
  • Visual trip indicator light gives quick notification of a tripped or end of life condition
  • Meets and exceeds 10 kA short circuit testing and Underwriters Laboratories (UL) UL943 safety standards
  • Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper is used
  • Tamper resistant shutters help prevent foreign objects from being inserted
  • Line side terminals are backed out and staked for fast installation
  • Horizontal test/reset button alignment provides larger unobstructed area
  • Test and reset buttons are color matched to provide superior aesthetics
  • Tapered back wire openings handle multiple wire sizes and types for applications up to 10 AWG solid or stranded wire
  • When downstream receptacles are wired from load side, a 20A feed through rating offers full protection
  • Line-load miswiring protection: GFCIs will not provide power downstream when wired incorrectly
  • Tri-combo head terminal and mounting screws
  • Longer, wider bridged strap provides 40% more contact area with wallboard, virtually eliminating floating installations
  • Thermoplastic, polypropylene; nylon 6/6 top housing, thermoplastic, PVC bottom housing, 0.047 in thick steel, zinc plated strap, 0.03 in thick brass line contacts materials
  • Brass/nickel plated steel terminal and ground screws, brass plated steel terminal clamps
  • Withstands 2000 V per UL498 dielectric voltage
  • V2 rated UL94 flammability
  • Current interrupting at full-rated current, 0.025 sec class A trip time, Short circuit testing meets and exceeds 10 kA, maximum interrupting capacity of 20 A
  • #14 to 10 AWG terminal accommodation, Back Wire and Side Wire