Eaton TRSGF15W
Eaton TRSGF15W GFCI TR Self Test Duplex 15A 125V WH
Receptacles
7463502
TRSGF15W
Eaton
$0.00
/ ea
- Amperage Rating: 15
- Color: White
- Dimensions: 4.2 in L x 1.68 in W x 1.27 in D
- Enclosure: IP65
- Frequency Rating: 60
- Material: Thermoplastic
- Nema Rating: NEMA 5-15R
- Number of Poles: 2
- Number Of Wires: 3
- Series: TRSGF
- Temperature Rating: -35 to 66
- terminal type: Back/Side Wire
- Type: Duplex Tamper-Resistant
- Voltage Rating: 125
Eaton ground fault circuit interrupter receptacle, 15A, 125V, Back wire and side wire, GFCI, White, Brass, Receptacle, Tamper resistant, PVC, 5-15R, Two-pole, three-wire, grounding
- Features
- If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow notifying the user there is no power and the device must be replaced
- Performs periodic self-tests to ensure integrity of GFCI protection
- Visual trip indicator light gives quick notification of a tripped or end of life condition
- Meets and exceeds 10 kA short circuit testing and Underwriters Laboratories (UL) UL943 safety standards
- Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper is used
- Tamper resistant shutters help prevent foreign objects from being inserted
- Line side terminals are backed out and staked for fast installation
- Horizontal test/reset button alignment provides larger unobstructed area
- Test and reset buttons are color matched to provide superior aesthetics
- Tapered back wire openings handle multiple wire sizes and types for applications up to 10 AWG solid or stranded wire
- When downstream receptacles are wired from load side, a 20A feed through rating offers full protection
- Line-load miswiring protection: GFCIs will not provide power downstream when wired incorrectly
- Tri-combo head terminal and mounting screws
- Longer, wider bridged strap provides 40% more contact area with wallboard, virtually eliminating floating installations
- Thermoplastic, polypropylene; nylon 6/6 top housing, thermoplastic, PVC bottom housing, 0.047 in thick steel, zinc plated strap, 0.03 in thick brass line contacts materials
- Brass/nickel plated steel terminal and ground screws, brass plated steel terminal clamps
- Withstands 2000 V per UL498 dielectric voltage
- V2 rated UL94 flammability
- Current interrupting at full-rated current, 0.025 sec class A trip time, Short circuit testing meets and exceeds 10 kA, maximum interrupting capacity of 20 A
- #14 to 10 AWG terminal accommodation, Back Wire and Side Wire