Wattstopper PW-302-I

WattStopper PW-302-I Dual Relay Wall Switch Occupancy Sensor, 120/277 VAC, Passive Infrared Sensor, 1050 sq-ft Coverage, 180 deg Viewing, Strap Mount
NEMA Transformers
7368687 PW-302-I
Wattstopper
$0.00 / ea

  • Color: Ivory
  • Connection Type: Flying Lead
  • Control Output: Automatic On/Off, Manual On/Off
  • Coverage: 1050
  • Dimensions: 2.73 in L x 1.75 in W x 1.81 in H
  • Lamp Type: LED
  • Material: Plastic
  • Mounting Type: Strap
  • Power Rating: 0 to 1200 W, 1/6 hp
  • Sensor Type: Passive Infrared
  • Series: PW Series
  • Temperature Rating: 35
  • Time Delay: 5 to 30
  • Type: Dual Relay
  • Viewing Angle: 180
  • Voltage Rating: 120/277
The PW-302 Passive Infrared (PIR) Wall Switch Sensor turns lights ON and OFF based on occupancy. It contains two relays for controlling two independent lighting loads or circuits, and a variety of features. (ivory)
  • Features
  • Time delay adjustments - 5 to 30 min at minimum, 3 minimum if no activity after 30 sec at walk through mode, 5 sec for 10 min with DIP switch setting at test mode
  • High or low (dip switch) PIR adjustment
  • 1000 W tungsten, ballast, E-ballast, LED, 1/4 hp load limit for relay 1 at 120 VAC, 1200 W ballast, E-ballast, LED, 1/4 hp load limit for relay 1 at 277 VAC, 800 W tungsten, ballast, E-ballast, LED, 1/6 hp load limit for relay 2 at 120 VAC, 1200 W ballast, E-ballast, LED, 1/6 hp load limit for relay 2 at 277 VAC
  • Complies with 2011 NEC requirements
  • Zero crossing for long relay life
  • Vandal-resistant lens combines precise coverage with durability
  • Selectable walk thorough mode turns lights off 3 min after the room is initially occupied if no motion is detected after the first 30 s
  • Test mode allows quick and easy adjustments
  • Selectable audible alert for impending shutoff
  • LED indicates occupancy detection
  • In automatic mode, sensor returns automatically to auto On after lights are turned Off manually, ideal for presentations
  • Optional light level sensing with simple setup
  • Service mode allows sensor to operate as a service switch in the unlikely event of a failure
  • Sensor coverage tested to NEMA guide publication WD 7 to 2000
  • Compatible with decorator wallplates
  • 2-relays for control of two separate lighting loads or circuits
  • Tungsten ballast E-ballast load type
  • Wall switch sensor turns lights off and on based on occupancy
  • It contains two relays for controlling two independent lighting loads or circuits
  • Optional neutral