Fluke FLUKE-381

Fluke® FLUKE-381 Clamp Meter, 999.9 A. 600 VAC, 1000 VDC, 60 kOhm, 500 Hz, 34 mm Jaw, Removable Wireless Display
Meters
7071387 FLUKE-381
Fluke
$0.00 / ea

  • AC Current Accuracy: 2% +/-5 Digits at 999.9 A, 3% +/-5 Digits at 2500 A
  • Dimensions: 10.9 in L x 3.46 in W x 1.69 in H
  • Display Type: Removable Wireless
  • Electrical Ratings: 999.9 A. 600 VAC, 1000 VDC
  • Frequency Rating: 500
  • Jaw Capacity: 34
  • Material: Hard Plastic
  • Operating Temperature: -10 to 50
  • Resistance: 60
  • Safety Rating: CAT IV 600 VAC/CAT III 1000 VAC
  • Voltage Accuracy: 1.5% +/-5 Digits at 1000 VAC, 1% +/-5 Digits at 1000 VDC
QTY
  • Features
  • Wireless technology allows the display to be carried up to 30 ft away from the point of measurement for added flexibility without interference with measurement accuracy
  • The removable magnetic display can be conveniently mounted where it is easily seen
  • IFlex® flexible current probe expands the measurement range to 2500 A AC
  • CAT IV 600 VAC/VDC, CAT III 1000 VAC/VDC
  • Integrated low pass filter and state-of the art signal processing allows for use in noisy electrical environments while providing stable readings
  • Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
  • Ergonomic design fits in your hand and can be used while wearing protective equipment
  • Radio transmitter automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
  • Soft carrying case
  • Accuracy - 2% +/-5 digits dc current/1.5% +/-5 digits (20 to 500 Hz) AC voltage/1% +/-5 digits dc voltage/ 1% +/-5 digits resistance
  • Resolution - 0.1 A AC current via jaw/0.1 A (
  • 2000 m operating altitude, 12000 m storage altitude
  • 7.5 mm flexible current probe diameter
  • 1.8 m flexible current probe cable length (head to electronics connector)
  • Add 0.1 x specified accuracy for each deg C above 28 deg C or below 18 deg C temperature coefficients
  • 3 at 500 A, 2.5 at 600 A, 1.42 at 1000 A, add 2% for C.F, >2 AC current via jaw/3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2% for C.F, >2 2 AC current via flexible current probe crest factor (50/60 Hz)
  • <=30 Ohm measure continuity
  • 100 ms measure inrush
  • Range 5 to 500 Hz frequency via jaw and flexible current probe, 600 Ohm/6 kOhm/60 kOhm resistance, 2% +/-5 digit (10 to 100 Hz), 5% +/-5 digit (100 to 500 Hz) via jaw, 3% +/-5 digit via flexible current probe AC current accuracy, 1.5% +/-5 digit (20 to 500 Hz) AC voltage, 1% +/-5 digit DC voltage accuracy