Coleman 25230001-6
Southwire reg; Surge Guard reg; 25230001-6 Type SJT In-Line User Attachable GFCI, 120 VAC, 20 A
Clamps and Straps
7188265
25230001-6
Coleman
$0.00
/ ea
Southwire Surge Guard In-Line User Attachable GFCI, Type SJT, 120 VAC, 20 A, 50/60 Hz, -35 to 66 deg C, 25 ms Response, Yellow, 6.4 in L x 2 in W x 1.86 in H
- Features
- The gfci in-line user attachable is ideal for existing equipment without GFCI protection and can be easily attached by connecting the gfci in series with the supply cable 9 to 10 inches from the plug end to provide GFCI protection
- GFCI is rainproof rated, UL listed for outdoor use
- To prevent unmonitored equipment startup, manual reset is required after GFCI trip and power outage
- Allows compliance with national electric code (NEC 2008) article 590.6 for temporary installations and OSHA regulation
- 4 Ohm typical grounded neutral
- 4 to 6 ma trip level
- Less than 25 ms trip response time for ground fault and grounded neutral trip
- 3 kV ringwave test and 4kv/2kA surge immunity test voltage surge withstand
- Operates within normal limits with 0.5 volts injected on power line 150 kHz to 230 MHz radio frequency noise susceptibility
- 3000 operations minimum endurance
- Six times rated current overload current
- 5% maximum trip level variation effect of 10 A turn DC shock on ground fault trip
- 1500 Vrms to 1 min insulation voltage
- Lighted indicator power on indication
- Manual reset
- Accepts 18 to 12 AWG (SJT)